d1 – microCT for Small to Medium Samples

High-Performance Linear Accelerator CT System for Analysing & Testing of High-Density Components

High-speed CT for large, heavy and dense components

  • Diondo d7 Linac CT for large heave and dense components

    Key Features

    • High-performance Linac - 3 MeV, 6 MeV and 9MeV with infinitely adjustable work areas
    • Automatic collimation - Switch between x and y at the touch of a button for superior image quality
    • Detector - High-resolution (140µm) flat panel optimised for Linac CT
    • Manipulator - Adapted to customer requirements
    • Loading crane - For samples up to 200kg
    • Completely customisable system layout - Tailored to suit your needs
    • Modular design - Minimises installation and commissioning time
    • Innovative radiation protection - Optimises space requirements
The diondo d1 excels by providing a fourfold increase in resolution for the same measurement time as other competitive systems. Similarly, it can achieve the same resolution as other systems, but four times faster. This increase in performance is due to the 240kV transmission X-ray tube with an ultimate target power of 80W. This makes it suitable for a range of applications including additive manufacturing, batteries, materials science (including fibre-reinforced composite materials) and metrology. This X-ray tube design contrasts with conventional reflection tubes where the high power required to penetrate dense/thick samples negatively impacts resolution. By their very design, higher power sources lead to lower resolutions. While this can be combated with longer scan times, that also brings with it obvious disadvantages. As mentioned, the transmission tube used in the diondo d1 architecture does not suffer from these disadvantages. Usability is further enhanced by the large X-ray detector. This large area detector with tightly spaced pixel grid enables both extremely high-resolution scanning of smaller samples and imaging of larger samples in one scan. This eliminates the need for time-consuming partial scans at the expense of precision. Diondo CT Systems Comparison ❮ dsubµd1d2d3d4d5d7 Highest Resolution Sub-Micron CT SystemHigh-Performance MicroCT SystemPowerful MicroCT SystemCompact CT System for High-Density PartsCompact CT System for High-Density PartsUniversal CT System with a Large Variety of ApplicationsHigh-Energy Linac CT Sample Size⚫⚪⚪⚪⚪⚪⚫⚫⚪⚪⚪⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚫ Sample Density⚫⚪⚪⚪⚪⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚫ Accuracy-⚫⚫⚫⚫⚫⚫⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚪⚪⚪⚪ Resolution⚫⚫⚫⚫⚫⚫⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚪⚪⚪⚪ Footprint⚫⚪⚪⚪⚪⚪⚫⚫⚪⚪⚪⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚪⚪⚫⚫⚫⚪⚪⚪⚫⚫⚫⚫⚫⚪⚫⚫⚫⚫⚫⚫ ...
  • All
  • Additive Manufacturing
  • Computed Tomography
  • Computed Tomography - Life Sci
  • Fluoroscopy
  • In situ
  • Radiography
  • X-ray Imaging
  • X-ray Microscopy